OTT PLS 500, Pressure Level Sensor, Modbus, Metric, 0 - 40 m

OTT PLS 500, Pressure Level Sensor, Modbus, Metric, 0 - 40 m
# de producto: 6303900190-M-M-3
Marca: OTT

Automatic Compensations​

Automatically compensate for changes in atmospheric pressure with the vented probe. Reduce the amount of equipment needed in field by forgoing additional barometric pressure sensors and achieve better accuracy with a single compensated sensor.

Position Sensor

Remotely monitor probe movement in the field with an internal inclinometer, enabling warnings if sensor position has changed due to in-stream events via automatic status flags or direct measurement. 

Internal Humidity Sensor​

The integrated internal humidity sensor outputs automatic status flags or direct humidity measurements to help you understand if condensation may have formed, impacting your pressure measurements.

Data Processing​

Internally convert high frequency (4 Hz) measurements to calculations such as computed averages, minimum/maximum levels, and instantaneous values over user defined intervals, enabling greater information reporting and eliminating manual data post-processing/analysis.

Discharge Calculations​

Automatically calculate discharge from either a user defined rating table or ISO 1100-2 exponential formula set-up via SDI-12 commands. Minimize the need for data post-processing by directly outputting discharge from a trusted level sensor.

Especificaciones

*Parámetros medidos: Water Level
Pressure
Temperature
Position of Sensor
Internal Relative Humidity
*Value Processing: Average pressure or level over measurement interval​
Median pressure or level over measurement interval​
Minimum pressure or level over measurement interval​
Maximum pressure or level over measurement interval​
Standard deviation of pressure or level over measurement interval​
Discharge
Body Material: Stainless steel 1.4539 (904L) resistant to sea water
Exactitud de la temperatura: ± 0.15 °C; Typ. ± 0.05 °C ( ± 0.07 °F; Typ. ± 0.03 °F)​
Exactitud nivel: Accuracy (linearity + hysteresis)
For all measuring ranges:
± 0.05 % full scale
Accuracy for 0 ... 10 m / 0... 1 bar variant
(Meets USGS OSW):
±2 mm / 0 ... 5 m (-5 … +55 °C)
±3 mm / 0 ... 5 m (-20 … -5 °C; +55 … +70 °C)
±5 mm / 5 ... 10 m (-20 … +70 °C)
0.007 ft / 0 ... 17 ft (+23 … +131 °F)
0.010 ft / 0 ... 17 ft (-4 … +23 °F; +131 … +158 °F)
0.017 ft / 17 ... 33 ft (-4 … +158 °F)
Fuente de alimentación: 5.5...28.8 V typically 12/24 V DC​
Grado de protección: IP68
Interfaz: SDI-12 and RS485 (SDI-12 v1.4 and Modbus RTU)
Power Consumption: Sleep: < 250 µA; typically 15 µA​
Active: < 4mA; typically 2.9 mA
Protocolo: Modbus (pre-configured)
Rango de medición: 0 - 40 m (0 - 131 ft)
Rango de temperatura: -20 °C (ice-free) ... +70 °C  (-4 °F ... +158 °F)
Resolución: 0.001 m / 0.1 cm / 0.00001 bar / 0.01 mbar (0.001 ft / 0.001 inch / 0.0001 psi)​
Resolución de temperatura: 0.01 °C (0.01 °F)
Unit System: Metric (pre-configured)