Kipp & Zonen WS50PV Compact All-in-One Weather Sensor

Kipp & Zonen WS50PV Compact All-in-One Weather Sensor
# de producto: OTT-8373.PV
Cód.Fabricante: 8373.PV
Marca: KIPP___ZONEN

Added confidence for energy production

PV site performance analysis is strengthened by correlating air temperature and wind speed with PV panel temperature data. The increased context of power production data offers peace of mind to ensure the solar system is meeting expectations as well as enabling more accurate alarms to be setup to detect system failures.

Reliable Accuracy

Data you can count on – ISO/IEC compliant with a lifetime expectancy greater than 10 years.

Hassle-free data

Focus on power generation, not sensor installation and maintenance. Five parameters combine in one housing, mount, and cable with a single digital output to any Modbus RTU-ready data acquisition system.

Modular

Easily add a precipitation or back of module temperature sensor to the same Modbus ID.

Especificaciones

*Parámetros medidos: Air Temperature
Air Pressure
Relative Humidity
Wind Direction
Wind Speed
Comunicación: Modbus®
Conexión de cable: Open Wires
Dimensiones: Ø150 x 287 mm
Dirección del viento: Accuracy: < 5° RMSE (wind > 1.0 m/s)
Measuring range: 0 - 359°
Resolution: 1°
Entradas analógicas: 1
Fastening: Ø 60 - 76 mm
Fuente de alimentación: Current consumption: 12 VDC, 85 mA; 24 VDC, 140 mA
Maximum consumption with heater on to support full ambient temperature range: 24 VDC ± 10 %, 20 VA
Grado de protección IP: IP66
Humedad de operación: 0 - 100 % RH
Humedad relativa: Accuracy: ±3 % RH
Measuring range: 0 - 100 % RH
Resolution: 0.1 %
Interfaz: RS485 2 wire
Baud rate: 1200 - 38400 bit/s (Standard: 19200)
Longitud de cable: 33 ft (10 m)
Material carcasa: Plastics (PC)
Peso: ˂ 1.2 kg
Presión de aire: Accuracy: ±0.5 hPa
Measuring range: 500 - 1100 hPa
Resolution: 0.1 hPa
Protocol over RS485: 2-wire, half-dublex
Rango de temperatura de operación: -40 - +60 °C
Tasa de salida: 1 min
Temperatura del aire: Accuracy: ±0.5 °C
Measuring range: -40 - +60 °C
Resolution: 0.1°C (-20 °C - +50 °C), otherwise 0.2 °C
Units: °C, °F
Wind Speed: Accuracy (0 - 35 m/s): ± 0.3 m/s or ± 3 %
Accuracy (>35 m/s):± 5 % of RMS
Measuring range: 0 - 50 m/s